Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bras Nefrol ; 34(4): 395-400, 2012.
Artigo em Português | MEDLINE | ID: mdl-23318830

RESUMO

Recent advances in prenatal diagnosis resulted in an improvement of detection and management of urinary tract abnormalities. Prenatal ultrasonography allows to identify urological abnormalities that otherwise would not be seen until later in life, when complications occur. The voiding cystourethrogram can be reserved for selected patients. Nuclear medicine exams should be performed in cases of moderate and severe hydronephrosis. A review of the current literature on postnatal approach of prenatal hydronephrosis was performed. Data obtained were compared with the records of the Pediatric Nephrology Unit HC/UFMG regarding management and follow-up of children with uropathies detected while investigating for fetal hydronephrosis.


Assuntos
Doenças Fetais/diagnóstico por imagem , Hidronefrose/complicações , Hidronefrose/diagnóstico por imagem , Ultrassonografia Pré-Natal , Sistema Urinário/anormalidades , Anormalidades Congênitas/diagnóstico , Diagnóstico por Imagem , Humanos , Recém-Nascido
2.
Obstet Gynecol Int ; 2011: 861865, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21765839

RESUMO

Purpose. It was to quantify the intraobserver and interobserver variability of the sonographic measurements of renal pelvis and classify hydronephrosis severity. Methods. Two ultrasonographers evaluated 17 fetuses from 23 to 39 weeks of gestation. Renal pelvis APD were taken in 50 renal units. For intraobserver error, one of them performed three sequential measurements. The mean and standard deviation from the absolute and percentage differences between measurements were calculated. Bland-Altman plots were used to visually assess the relationship between the precision of repeated measurements. Hydronephrosis was classified as mild (5.0 to 9.9 mm), moderate (10.0 to 14.9 mm), or severe (≥15.0 mm). Interrater agreement were obtained using the Kappa index. Results. Absolute intraobserver variation in APD measurements was 5.2 ± 3.5%. Interobserver variation of ultrasonographers was 9.3 ± 9.7%. Neither intraobserver or interobserver error increased with increasing APD size. The overall percentage of agreement with the antenatal hydronephrosis diagnosis was 64%. Cohen's Kappa to hydronephrosis severity was 0.51 (95% CI, 0.33 to 0.69). Conclusion. Inter and intraobserver APD measurement errors were low in these group, but the agreement to hydronephrosis diagnosis and classification was fair. We suggest that standard and serial APD measurement can better define and evaluate fetal hydronephrosis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...